Pennsylvania deck permits
In Philadelphia, the EZ deck size limit depends on the post layout. In Pittsburgh, adding a roof changes which drawings need a professional stamp.
Official sources checked
On this page
Where to start in Pennsylvania
Look up the municipality in Pennsylvania’s Uniform Construction Code directory. In an opt-in municipality, contact the listed building code official. In an opt-out municipality, the owner hires a certified third-party agency for residential code enforcement. Check zoning with the municipality serving the lot.
Local filing requirements
Pittsburgh
- Start a Building and Development Application in OneStopPGH. The city requires a site plan stamped by a Pennsylvania architect, engineer or surveyor. Measure from finished grade to the finished deck surface and identify any roof.
- For an uncovered deck up to 30 inches above grade, construction drawings are generally unnecessary. Above 30 inches through 8 feet, add structural drawings or, for a deck that meets the referenced wood deck guide, the city’s Residential Deck Application.
- For a covered deck or one over 8 feet above finished grade, include construction drawings prepared and stamped by a Pennsylvania architect or engineer along with the stamped site plan.
Philadelphia
- For a new rear deck attached to an existing single-family home, the EZ standard allows up to 160 square feet, or up to 216 with intermediate posts. A 12-by-16-foot deck is 192 square feet, so its post layout matters. Check the remaining conditions on the city sheet before applying.
- The deck must be at or below the first floor and open above. Stairs to grade are allowed only at detached or semi-detached homes. Eligible projects still need zoning and building permits. Apply through eCLIPSE or at the Permit and License Center.
Covered deck in Pittsburgh
Open sheet 5 at full size (PDF) The deck on sheet 5 has a roof and stands 9 feet 11 inches above grade at the downhill end. Either condition calls for stamped construction drawings in Pittsburgh. Removing the roof from this design would still leave it over the 8-foot limit.